You are here:Home>TSCM equipment>Counter espionage devices>Acoustic and Vibroacoustic Noise Generators>DNG-KIT 1 - Vibro-acoustic Protection Kit

DNG-KIT 1 - Vibro-acoustic Protection Kit

It is well-known that sound permeates through walls, doors, water, windows and other constructions as well as through voids, cavities and ventilation shafts. This property of materials makes it possible to intercept conversations conducted within a premises with the help of highly sensitive contact microphones (electronic stethoscopes), window laser systems or conventional microphones without entering the target area.
Wall contact microphones can pick up vibrations from the plumbing, structures, walls, windows, doors, floors, ceilings and more. The listening device may be in an adjacent room, or even several floors or rooms away attached to a wall, pipe or other fixture. Cavities such as air ducts, ventilation shafts or other voids can be used for intercepting sound from an adjacent premises with a help of conventional microphones.
Window laser systems are able to "read" conversations from the premises by sending visible, or invisible, infrared beams to the glass and extracting the sound vibrations from the reflected rays.
The DNG-2300 generator, together with its transducers and speakers, counteracts all the above mentioned methods of listening by creating powerful, non-filterable interference on the structure of a building and within its voids. While transducers inject their generated noise into surfaces and structures, stopping the distribution of sound through them, the role of a speaker is to fill voids, cavities and ventilation shafts with audio interference to prevent leakage of sound through the air.
 
FEATURES
-Creates powerful protection against the leakage of all types of vibro-acoustics by injecting non-filterable noise into surrounding structures and cavities
-Suppresses wall contact microphones, window laser systems and wired microphones inside walls, voids and ventilation shafts (air ducts)
-Is a key part of the protection system which also includes wire-connected transducers and speakers
-Generates white noise – the output interference is evenly distributed through the spectrum of a human's voice
-All 3 channels have individual level adjustment
-Each TRANSDUCERS channel can feed up to 12 transducers mounted on solid structures (concrete/cement/bricks) and up to 24 transducers on light structures (glass, pipes, drywall, wood)
-The SPEAKERS channel can feed up to 12 speakers
-The MUTE control input allows the user to turn off the speakers temporarily
 
 
KIT CONTAINS
Noise generator DNG 2300 - 1 pc
AC power cord - 1 pc
Transducer TD2300 4 Ohm - 12 pcs
Speaker SP2300 - 2 pcs
Carry case - 1
Technical Specifications
DNG-2300
Power source 110-220V, 50 60Hz
Dimensions 6×17.5×25.4 cm
Weight 2.2 Kg
Output channels 2 x TRANSDUCERS
1 x SPEAKERS
Peak output voltage 12V
TRANSDUCERS output (2)  
Max. output power: 2 × 10W
Frequency response: 180-5600 Hz
Min. impedance of load: 3 Ohm
Recommended transducer: TD2300
Max. quantity of transducers per channel: 24 (light structures); 12 (solid structures)
SPEAKERS output  
Max. output power: 1 x 8W
Frequency response: 180-7000 Hz
Min. impedance of load: 8 Ohm
Recommended speaker: SP2300
Max. quantity of speakers: 12

pdf

Download DNG-KIT-1-Datasheet-ENG pdf

Size : 669.66 kb
Hits : 61
pdf

Download DNG-2300-User-manual-ENG pdf

Size : 869.54 kb
Hits : 93

  • Request More Info

CONTACTS

Address:
Silutes pl. 2 (Office No 525, 5th floor),
Klaipeda 91111, Lithuania
Phone: +370 655 08288, +370 655 08286
Fax: +370 46 411353
E-mail: info@selcomsecurity.com
zemelapis